(Return to Conductivity Sensors)
 

Model CS52B-TRI Conductivity Sensor
Click on part number above to request an RFQ or place an order online.
  • Very compact size for a high probe constant sensor
  • O-ring seals used on all versions for high on-stream reliability
  • Thermowell for the temperature element assures rapid response
This sensor was designed for open tank applications where it is desired to suspend the sensor or its cable rather than using a stand-pipe. Its most common application is in the plating industry, where it minimizes extra hardware in and around the tanks with their highly corrosive chemicals.

Application Notes
Wetted materials of construction are 316 stainless steel and CPVC, with double EPR o-ring seals. The outer o-ring is the only one to touch the process fluid, allowing the rear seal to operate free from chemical attack. The thermowell containing the temperature sensing element in its tip is exposed directly to the stream, assuring rapid automatic compensation for maximum accuracy.

Process connections are customer are 3/4" NPT for insertion, and the back portion is a barbed fitting for 1/2" ID flexible tubing attachment. The sensor can be suspended by its cable without undue strain on the wires, or intrusion of chemicals down the stretched cable insulation. This allows extremely simple and inexpensive installations that do not require standpipes, brackets, etc.

SPECIFICATIONS

MAX. PRESSURE/TEMP. RATINGS:
100 PSIG at 95°C

CONNECTIONS:
Pocess - 3/4" NPT, or barbed fitting for connection of 3/8" ID flexible tubing so that sensor can be suspended by its cable into an open tank or stream without damage to the wires or insulation from strain or liquid. Electrical - Spade lug terminations on cable.

WETTED MATERIALS:
Insulator - Teflon
0-rings - EPR
Electrodes - 316SS

PROBE CONSTANT:
10.0

TEMPERATURE COMPENSATION:
Standard element is 10KΩ @ 25°C, for use with SDI, Uniloc, Myron L, Sensor Technology, Signet, ECD and others. Other TC's available by specifying instrument make and model.