(Return to Conductivity Sensors)
 

Model CSxx-TRI Conductivity Sensor
Click on part number above to request an RFQ or place an order online.
  • Designed for insertion into Ladish or Tri-Clover fittings.
  • 0-ring seals used on all versions for high on-stream reliability.
  • Easily withstands steam sterilization.
The CS10, CS51 and CS52 sensors are welded to blind flanges of customer specified size, and can then be inserted into standard tee fittings in sanitary systems using Ladish or Tri-Clover fittings.

Physical Description
Wetted materials of construction are 316 stainless steel and Teflon, with double redundant EPR o-ring seals. The process side o-ring is the only one in contact with the stream, allowing the back o-ring to maintain reliable sealing, free from chemical attack. TC elements are potted in the body itself. Leads are 10' standard.
Process connections are customer specified sanitary blind flanges. The insertion depth is tailored for each flange size to obtain proper positioning in the standard tee fittings of the given piping system. The sensor is amenable to both steam sterilization, or cleaning by any of the commonly used sanitizing solutions such as bleach, ozone, etc..

SPECIFICATIONS

MAX. PRESSUREITEMP. RATINGS:
100 PSIG at 120°C

CONNECTIONS:
Process - #16AMP solid end cap by Tri-Clover, for installation on side branch of Tri-Clover #7MP tee, size specified by customer. Electrical - Spade lug terminations on cable.

WETTED MATERIALS:
Insulator - Teflon
0-rings - EPR
Electrodes - 316SS

PROBE CONSTANT:
CS10 - 0.1/0.05/0.02
CS51 - 1.0/0.1

TEMPERATURE COMPENSATION:
Standard element is 10KΩ @ 25°C, for use with SDI, Uniloc, Myron L, Sensor Technology, Signet, ECD and others. Other TC's available by specifying instrument make and model.